50-State 811 Utility Daylighting & Hydro-Vac Laws

State-by-state Underground Utility Damage Prevention Acts, 811 Call-Before-You-Dig tolerance zone boundaries (18″ to 24″ on each side of marked line), mandatory non-destructive vacuum hydro-excavation daylighting before power equipment digging, and pipeline safety codes.

State Governing Underground Damage Prevention Authority Statutory Tolerance Zone (Each Side of Mark) Mandatory Non-Destructive Hand / Hydro-Vac Rule High-Pressure Gas / Petroleum Pipeline Exposure
AlabamaAlabama 811 / Alabama PSC (Title 37-15)18 inches + half diameterMandatory hand dig or vacuum hydro-excavationPHMSA / Pipeline Operator on site
AlaskaAlaska 811 (Alaska Statute 42.30.400)24 inches on all sidesMechanical digging banned until visual contactSpecial safety watch for gas mains
ArizonaArizona Blue Stake / ACC (A.R.S. § 40-360.21)24 inches on all sidesMandatory vacuum hydro-excavation / soft digPipeline operator standby required
ArkansasArkansas 811 / Arkansas PSC (Ark. Code § 14-271)18 inches + half diameterNon-mechanical soft digging requiredTransmission line emergency protocol
CaliforniaUSA North 811 & DigAlert / CA Dig Safe Board (Gov Code § 4216)24 inches on all sidesMandatory non-destructive vacuum hydro-vacStrict CPUC high-priority gas safety
ColoradoColorado 811 / Safety Commission (C.R.S. § 9-1.5)18 inches + half diameterMandatory soft digging / vacuum excavationCritical infrastructure daylighting
ConnecticutCall Before You Dig (CBYD) / PURA (CGS § 16-345)18 inches on all sidesHand or vacuum excavation mandatoryHigh pressure transmission watch
DelawareMiss Utility of Delmarva / PSC (26 Del. C. § 8)24 inches on all sidesMechanical excavation prohibited in zonePipeline operator notification
FloridaSunshine 811 / Florida PSC (Chapter 556 FS)24 inches on all sidesMandatory soft excavation / hydro-vacHigh-consequence pipeline daylighting
GeorgiaGeorgia 811 / Georgia PSC (O.C.G.A. § 25-9)18 inches + half diameterMandatory hand tools or vacuum hydro-excavationMandatory utility representative on site
HawaiiHawaii One Call Center / PUC (HRS § 269E)24 inches on all sidesNon-destructive exposure requiredTransmission main standby
IdahoDig Line 811 / Idaho PSC (Idaho Code § 55-22)24 inches on all sidesHand digging or hydro-vac mandatoryGas pipeline operator clearance
IllinoisJULIE 811 & Chicago 811 / ICC (220 ILCS 50)18 inches on all sidesMechanical digging prohibited until exposedPeoples Gas / Nicor high-pressure watch
IndianaIndiana 811 / IURC (IC § 8-1-26)24 inches on all sidesMandatory vacuum hydro-excavation in zoneMandatory pipeline daylighting
IowaIowa One Call / Iowa Utilities Board (Iowa Code § 480)18 inches on all sidesPrecise soft dig exposure mandatoryTransmission pipeline verification
KansasKansas One-Call / KCC (K.S.A. § 66-1801)24 inches on all sidesNon-mechanical methods requiredGas operator safety standby
KentuckyKentucky 811 / Kentucky PSC (KRS § 367.4901)18 inches + half diameterHand tools or non-destructive hydro-vacCritical petroleum pipeline exposure
LouisianaLouisiana 811 / Louisiana PSC (La. R.S. § 38:2223)18 inches on all sidesMandatory soft dig / hydro-excavationPetrochemical pipeline corridor rules
MaineDig Safe 811 / Maine PUC (23 MRSA § 3360-A)18 inches on all sidesHand tools or vacuum excavationNatural gas main exposure protocol
MarylandMiss Utility 811 / MD Authority (PUA § 12-101)18 inches on all sidesNon-destructive hydro-vac mandatoryBGE / Washington Gas pipeline watch
MassachusettsDig Safe 811 / DPU (M.G.L. c. 82 § 40)18 inches on all sidesMechanical digging strictly banned in zoneHigh pressure gas daylighting required
MichiganMISS DIG 811 / MPSC (Public Act 174)48 inches (24″ each side)Mandatory soft excavation / hydro-vacEnbridge / DTE pipeline standby
MinnesotaGopher State One Call (GSOC) / DPS (Minn. Stat. § 216D)24 inches on all sidesHand tools or vacuum hydro-excavationHigh-pressure petroleum daylighting
MississippiMississippi 811 / Mississippi PSC (Miss. Code § 77-13)18 inches on all sidesSoft dig exposure mandatoryTransmission pipeline verification
MissouriMissouri 811 / Missouri PSC (RSMo § 319.015)24 inches on all sidesHand digging or non-destructive vacuumSpire Gas / pipeline daylighting
MontanaMontana 811 / Montana PSC (MCA § 69-4-501)18 inches on all sidesMechanical power equipment banned in zoneNorthWestern Energy pipeline standby
NebraskaNebraska811 / Nebraska AG (Neb. Rev. Stat. § 76-2301)18 inches + half diameterNon-destructive soft excavation requiredBlack Hills / OPPD pipeline clearance
NevadaUSA North 811 / PUCN (NRS § 455.080)24 inches on all sidesMandatory vacuum hydro-vac exposureSouthwest Gas transmission safety
New HampshireDig Safe 811 / NH DOE (RSA § 374:48)18 inches on all sidesHand tools or vacuum excavationGas transmission line exposure
New JerseyNJ One Call / NJ BPU (N.J.S.A. § 48:2-73)24 inches on all sidesMandatory non-destructive hydro-vacPSE&G / NJNG high-pressure gas watch
New MexicoNew Mexico 811 / PRC (NMSA § 62-14)24 inches on all sidesSoft digging or hydro-vac requiredOil/gas gathering line daylighting
New YorkDig Safely NY (UDIG NY) / NYS PSC (16 NYCRR Part 753)24 inches on all sidesPower equipment banned without visual daylightingConEd / National Grid high-pressure safety
North CarolinaNC811 / NC Utilities Commission (NCGS § 87-115)24 inches on all sidesMandatory soft excavation in tolerance zonePiedmont / Dominion pipeline watch
North DakotaNorth Dakota One Call / PSC (NDCC § 49-23)24 inches on all sidesHand or vacuum excavation mandatoryBakken oil/gas pipeline daylighting
OhioOHIO811 / PUCO (ORC § 3781.25)18 inches + half diameterMandatory non-destructive soft digColumbia Gas / high-pressure exposure
OklahomaOkie811 / Oklahoma Corporation Commission (Title 63 § 142)24 inches on all sidesSoft dig or vacuum excavation requiredMidstream pipeline exposure verification
OregonOregon 811 / OPUC (OAR 952-001)24 inches on all sidesMandatory non-destructive hydro-vacNW Natural gas pipeline daylighting
PennsylvaniaPA One Call 811 / PA PUC (Act 287 as amended)18 inches + half diameterPower equipment prohibited until daylightedMarcellus Shale transmission pipelines
Rhode IslandDig Safe 811 / RI DPUC (RIGL § 39-1.2)18 inches on all sidesHand tools or vacuum hydro-excavationNational Grid gas line clearance
South CarolinaSC811 / SC ORS (SC Code § 58-36)24 inches on all sidesMandatory soft dig / hydro-vacHigh-pressure transmission standby
South DakotaSouth Dakota 811 / PUC (SDCL § 49-7A)18 inches on all sidesHand tools or vacuum excavationPipeline operator safety clearance
TennesseeTennessee 811 / TPUC (TCA § 65-31)24 inches on all sidesMandatory soft digging / hydro-vacTVA / Piedmont gas pipeline watch
TexasTexas811 / Railroad Commission of Texas (Texas TAC Title 16)18 inches on all sidesMandatory soft dig / vacuum hydro-vacRRC Class 1-4 pipeline daylighting
UtahBlue Stakes of Utah 811 / PSC (Utah Code § 54-8a)24 inches on all sidesMechanical digging prohibited in zoneDominion Energy gas line verification
VermontDig Safe 811 / Vermont PSB (30 V.S.A. § 7001)18 inches on all sidesHand tools or vacuum excavationVermont Gas transmission clearance
VirginiaVirginia 811 / State Corporation Commission (Va. Code § 56-265)24 inches on all sidesMandatory non-destructive soft digColonial / Columbia Gas pipeline standby
WashingtonWashington 811 / UTC (RCW § 19.122)24 inches on all sidesMandatory vacuum hydro-excavationPuget Sound Energy pipeline daylighting
West VirginiaWV811 / WV PSC (WV Code § 24D-1)24 inches on all sidesPower equipment banned in zoneAppalachian gas gathering exposure
WisconsinDiggers Hotline 811 / PSC (Wis. Stat. § 182.0175)18 inches on all sidesHand or vacuum excavation mandatoryWe Energies / pipeline safety watch
WyomingOne-Call of Wyoming / WY PSC (W.S. § 37-12-301)24 inches on all sidesSoft dig exposure mandatoryOil/gas high-pressure pipeline clearance